QT2256 - 320PXI - Combination Board Tester
Digital Subsystem

General configuration is 64 channel high current force driving pin drivers and 192 normal 50 ohms drivers to make up to 256 test channels. Each digital card has 32 channels. Maximum 320 digital channels can be configured in steps of 32 channel cards

Pin Driver / Sensor modules:

 50 Ohms Pin Driver / Sensor modules (+8,-3V)Force Driving Pin Driver / Sensor (+/-10V)
Maximum Skew at Front Panel:+/- 5ns+/- 10ns
Driver Source impedance50 Ohms +/- 5%8 Ohms +/- 10%
Slew Rate600V / microsecs.200V / microsecs.
Source Currentstatic:85mA400mA
 dynamic:100mA650mA
Sink Currentstatic:85mA400mA
 dynamic:100mA650mA
Comparator Loading - - - - - - - - - - DC load 1 M Ohm with 10 pF - - - - - - - - - -
Optional Programmable load current in the range of+/-35mA+/-50mA

Analog Subsystem

System supports up to four analog channels at 20MHz sampling speed. These can be used for Mixed Signal and analog Test, used as PMUs or used in In-Circuit Measurement of RLC values.

1) As Analog Channels for Testing Analog / Mixed Signal Devices :
Four Independent Analog Channels can be multiplexed to any of the 320 Test channels +8 Flying Channels.

Drive Pattern memory (Analog):12 X 1M per Pin
Receiver Memory (Analog):12 X 1M per Pin
VOLTAGE / CURRENT:In six ranges up to +/- 13 V and +/- 260 mA
Programmable source impedences:10E, 100E, 1k, 10k, 100k, 1M and open
2) As PMU (Precision Measurement Unit)
Number of PMUs:Four multiplexed to any of the 320 channels using ultra fast reed relay.
Force Voltage-Measure Current mode with 6 ranges.
Capable of forcing voltage from +/-13v and current measure from +/-100mA to +/-130 nA.
Force Current-Measure Voltage mode with 6 ranges.
Capable of forcing current from +/-100mA and voltage measure compliance of +/-10v
3) As QSM VI channels:
Fully user programmable VI trace drive patterns.
Frequency from DC to 100KHz
Source impedance from 10 ohms to 1 Meg ohm
Voltage range from 0.6v to 13v
Drive pattern length is user programmable up to 1 Meg samples
4)As RLCV Measurement unit:
Measure Voltage Range: +/-13v.
Measure Resistance Range: 10 ohms to 1 Meg Ohm,
Measure Capacitance: 10pF to 10,000UF,
Measure Inductance from 10uH to 10H