| 1) As Analog Channels for Testing Analog / Mixed Signal Devices : |
Four Independent Analog Channels can be multiplexed to any of the 320 Test channels +8 Flying Channels.
|
| Drive Pattern memory (Analog) | : | 12 X 1M per Pin |
| Receiver Memory (Analog) | : | 12 X 1M per Pin |
| VOLTAGE / CURRENT | : | In six ranges up to +/- 13 V and +/- 260 mA |
| Programmable source impedences | : | 10E, 100E, 1k, 10k, 100k, 1M and open |
|
| 2) As PMU (Precision Measurement Unit) |
| Number of PMUs | : | Four multiplexed to any of the 320 channels using ultra fast
reed relay.
|
| Force Voltage | - | Measure Current mode with 6 ranges.
Capable of forcing voltage from +/-13v and current measure from +/-100mA to +/-130 nA. |
| Force Current | - | Measure Voltage mode with 6 ranges.
Capable of forcing current from +/-100mA and voltage measure compliance of +/-10v |
|
| 3) As QSM VI channels: |
Fully user programmable VI trace drive patterns. |
Frequency from DC to 100KHz |
Source impedance from 10 ohms to 1 Meg ohm |
Voltage range from 0.6v to 13v |
Drive pattern length is user programmable up to 1 Meg samples |
|
| 4)As RLCV Measurement unit: |
Measure Voltage Range: +/-13v. |
Measure Resistance Range: 10 ohms to 1 Meg Ohm, |
Measure Capacitance: 10pF to 10,000UF, |
Measure Inductance from 10uH to 10H |