Home What's New Careers Products Customer Support Downloads About Us

CATS-100 PCB test diagnostic system trainer
Specifications

Digital Test Capabilities
Drive / Sense channels -48 channels.
Drive / Sink capability - 220 mA per channel. Fixed drive levels for zero, tristate and +5v.
Sense Threshold - Programmable from 0v to 5.12v in steps of 20mv / step.
RAM behind each drive - 8k x 2 RAM.
Test speed - Programmable from a maximum of 2 micro seconds to 512 micro seconds per tick in 9 steps.
Guard channel - 8 channels programmable to 0v, 5v or Tristate.
Library - TTL, CMOS, INTERFACE, LSI, VLSI, Analog devices and User libraries.
Diagnostic software - Qmax CATS-100 software runs under MS-Windows'95.
Test Language - Qmax CATS-100 IDDE software with QDDL, WEST and GTPG.
DUT power supply - +/- 5v @ 20 amps Auto Switch on/off under program control.
Functions - Power on In-circuit Functional Test, Unknown Device identify, Automatic Circuit compensation, Automatic pull up for open collector Testing, Board Learn / Test functions with auto guarding guide, Board Functional test through card edge, Cluster testing, User expandable test library, In-circuit Resistor / Capacitance measurement. Power on pin status indication for pin Floats, links, Voltages and impedance, Logic Analyser waveform display, clear PASS / FAIL indication for ease of use, Variable Test Speed, Circuit Tracer function, Integrated Testing of ICFT, QSM / VI in one operation.
 
Analog Test Capabilities
Drive / Sense channels - 2 Analog channels to any of the 48 channels and 2 sets of movable probe.
Drive / Sense capability - +/- 10mA max; +/- 32v max.
RAM behind channels - 8k x 8 bits each drive and sense channels.
Data rate - 2 micro seconds per tick to 16 milli seconds per tick in steps.
Drive pattern - Sine, Ramp, Triangle, Square or user definable.
Functions - Functional Test for Op-Amps, Comparators, Transistors, SCR, FETS in Out-Circuit mode.
 
QSM and VI Trace
Channels - 64 Channels.
Probes - 2 probes with 2 reference signals inputs for QSM.
Voltage range - +/- 2.5v, +/- 8v, +/- 19v, +/- 32v. Current range from 0.24mA to max. of 10mA.
Frequencies - 40 Hz, 312 Hz, 2.5 KHz.
Drive pattern - Sine or as required.
Function - QSM, VI, Impedance and Voltage measurements.
 
Short Locator
Ranges - 3 Ranges at 200 milli ohms, 2 ohms and 200 ohms using 4 wire measurements.
Resolution - 800 micro ohms in 200 milli ohms range.
Display - Bar Graph, Digital readout and Audible sound.